Battery Energy Storage System (BESS) | The Ultimate Guide

25 Aug.,2025

 

Battery Energy Storage System (BESS) | The Ultimate Guide

How does a battery storage system work?

A BESS collects energy from renewable energy sources, such as wind and or solar panels or from the electricity network and stores the energy using battery storage technology. The batteries discharge to release energy when necessary, such as during peak demands, power outages, or grid balancing. In addition to the batteries, BESS requires additional components that allow the system to be connected to an electrical network.

A bidirectional inverter or power conversion system (PCS) is the main device that converts power between the DC battery terminals and the AC line voltage and allows for power to flow both ways to charge and discharge the battery. The other primary element of a BESS is an energy management system (EMS) to coordinate the control and operation of all components in the system.

Read more

BESS Power and Energy Ratings

For a battery energy storage system to be intelligently designed, both power in megawatt (MW) or kilowatt (kW) and energy in megawatt-hour (MWh) or kilowatt-hour (kWh) ratings need to be specified.

The power-to-energy ratio is normally higher in situations where a large amount of energy is required to be discharged within a short time period such as within frequency regulation applications. For pricing purposes, however, the quoted measure is usually the energy rating.

What is the Battery C‐Rate?

A battery’s C rating is the rate at which a battery can be fully charged or discharged. For example, charging at a C-rate of 1C means that the battery is charged from 0 - 100% or discharged from 100 - 0% in one hour.

A C-rate higher than 1C means a faster charge or discharge, for example, a 2C rate is twice as fast (30 minutes to full charge or discharge). Likewise, a lower C-rate means a slower charge or discharge, as an example, a C-rate of 0.25 would mean a 4-hour charge or discharge.

The formula is:
T = Time
Cr = C-Rate

T = 1 / Cr (to view in hours), or T = 60 min / Cr (to view in minutes). For example:

C-Rate Time 2C 30 minutes 1C 1 hour 0.5C 2 hours 0.25C 4 hours

Advantages of battery energy storage systems

Battery storage systems have several advantages when paired with renewable energy and non-renewable forms of generation. Solar and wind can be unpredictable, so battery storage systems are a key component in steadying energy flow by providing a steady supply whenever required, irrespective of weather conditions. Additionally, BESS can protect users from potential supply interruptions that could threaten the energy supply. Here are some of the benefits of battery storage systems:

Environmental

Installing a battery energy storage system powered by renewable energy generation technologies helps reduce carbon emissions from fossil fuels and contributes to the net zero pathways in combatting the effects of global warming.

Reduce energy costs

BESS allows consumers to store low-cost solar energy and discharge it when the cost of electricity is expensive. In doing so, it allows businesses to avoid higher tariff charges, reduce operational costs and save on their electricity bills.

Reduce grid dependency

Battery storage systems guarantee a continuous energy supply, even at times when the network is unstable due to peaks in demand or extreme weather events.

“Always on” supply

The sun is not always “on.” A battery storage system works round the clock and therefore compensates for any fluctuations in solar energy supply by storing any excess energy and maximise renewable energy generation.

Enhanced Resilience

A full battery energy storage system can provide backup power in the event of an outage, guaranteeing business continuity.

Co-location of Assets

Battery systems can co-locate solar photovoltaic, wind turbines, and gas generation technologies. In doing so, BESS co-location can maximise land use and improve efficiency, share infrastructure expenditure, balance generation intermittency, lower costs, and maximise the national grid and capacity.

Frequency Control

The battery energy storage system can regulate the frequency in the network by ensuring it is within an appropriate range. Discrepancies between generated and required energy can cause short-term problems, such as outages or blackouts, but BESS can quickly react and secure sub-second frequency response, stabilising the network. Additionally, it guarantees voltage stability by keeping it within established boundaries.

In summary:

  • Battery storage can improve the reliability, availability, and efficiency of the power supply
  • BESS solutions can accelerate decentralised power station infrastructure which can add value to commercial and utility-scale power generation models
  • Battery storage has no significant restriction on the geographical locations that it can be sited in. Storage technologies such as pumped hydro and compressed air are only suitable for a limited number of places
  • High energy density (resulting in reduced footprint) and fast response time (<150ms achievable)

Battery Energy Storage System Components

BESS solutions include these core components:

Battery System or Battery modules – containing individual low voltage battery cells arranged in racks within either a module or container enclosure. The battery cell converts chemical energy into electrical energy. The batteries are connected in series and parallel for the required capacity.

Storage enclosure - either as an outdoor module or containerised solution along with thermal management.

Battery Management System (BMS) – which ensures the battery cell's safe working operation, ensuring it operates within the correct charging and discharging parameters. In doing so, the BMS monitors the battery cell's current, voltage, and temperature and estimates its state of charge (SoC) and State-of-Health (SoH) to prevent safety risks and ensure reliable operation and performance.

Inverter or a Power Conversion System (PCS) – the battery cell produces direct current (DC), which the PCS converts into alternating current (AC) used for the power grid, commercial or industrial applications. Bidirectional inverters allow for the charging and discharging of the battery cell.

Energy Management System (EMS) – controls and monitors the energy flow of the BESS and systems. The EMS coordinates the BMS, inverters and other components of the battery energy system by collecting and analysing data used to manage and optimise the overall system performance.

Safety Systems – subject to system functionality and operating conditions, a BESS will include fire suppression, smoke detection, a temperature control system, and cooling, heating, and air conditioning systems. A dedicated monitoring and control system will ensure the safe operation of the BESS and the prevention of fire and hazardous incidents. The BESS will also be housed within a secure restricted access area and include CCTV monitoring.

Principal BESS characteristics

Rated Power Capacity

Rated Power Capacity is the total discharge capability (usually in megawatts (MW)) or the maximum rate of discharge the BESS can achieve, starting from a fully charged state.

Rated Energy Storage

Rated Energy Storage Capacity is the total amount of stored energy in kilowatt-hours (KWh) or megawatt-hours (MWh). Capacity expressed in ampere-hours (100Ah@12V for example).

Storage Duration

The amount of time storage can discharge at its power capacity before exhausting its battery energy storage capacity. For example, a battery with 1MW of power capacity and 6MWh of usable energy capacity will have a storage duration of six hours.

Depth of Discharge (DoD)

Depth of Discharge (DoD) expresses the total amount of capacity that has been used.

Cycle life / lifetime

The amount of time or cycles a battery storage system can provide regular charging and discharge before failure or significant degradation. Cycle Life is the number of times a battery storage part can be charged and discharged before failure, often affected by Depth of Discharge (DoD), for example, one thousand cycles at a DoD of 80%.

Self-discharge

Self-discharge occurs when the battery's stored charge (or energy) is reduced through internal chemical reactions or without being discharged from performing work for a customer or the grid. Self-discharge is usually expressed as a percentage of the charge lost over a certain period. It is an essential parameter in batteries intended for longer-duration applications.

Discharge Rate

Discharge Rate (C) describes the current that a battery can deliver for a period of time, as an example, C5 is the current a battery will provide over 5 hours to reach full discharge.

State of Charge

The state of charge is usually expressed as a percentage representing the battery's present charge level and ranges from wholly discharged to fully charged. The state of charge influences a battery's ability to provide energy or ancillary services to the network at any given time. The state of Charge expresses the amount of capacity remaining.

Round-trip Efficiency

Round-trip efficiency is the ratio of energy charged to the battery to the energy discharged from the battery and is measured as a percentage. It can represent the battery system's total AC-AC or DC-DC efficiency, including losses from self-discharge and other electrical losses.

In addition to the above battery characteristics, BESS have other features that describe its performance.

Ramp Rate

The ramp rate is the rate at which the BESS may decrease or increase its power output - ramp down or up, respectively.

Response Time

The response time is when BESS must move from the idle state and start working at full power.

Types of Battery Chemistries

Lithium-Ion (Li-Ion)

Lithium iron phosphate (LFP) and lithium nickel manganese cobalt oxide (NMC) are the two most common and popular Li-ion battery chemistries for battery energy applications. Li-ion batteries are small, lightweight and have a high capacity and energy density, requiring minimal maintenance and provide a long lifespan. Lithium-ion batteries can also be rapidly charged and have a low self-discharge rate.

The disadvantages of this battery technology include excessive cost, inflammability, intolerance to extreme temperatures, overcharge, and over-discharge.

Lead-Acid (PbA)

Lead-Acid batteries are well-proven within the automotive industry and behind-the-meter grid and UPS applications. PbA batteries are widely available, low cost, widely recyclable, and can perform effectively at both hot and cold temperatures. However, due to advances in Li-ion battery technology, lead-acid batteries have a low energy density and are slow to charge.

Sodium-Sulphur (Na-S)

A sodium-sulphur battery is a molten salt-based device. Na-S batteries have several advantages, including high energy and power density, a long lifespan, and reliable operation under extreme 300 to 350 degrees Celsius temperatures. However, this battery technology is primarily suited to large-scale stationary grid storage applications due to high operating temperatures and corrosion sensitivity. Sodium is also a dangerous component because it is highly flammable and potentially explosive.

Flow Batteries

Flow batteries store energy in liquid electrolyte solutions, unlike traditional rechargeable battery solid electrode material. The vanadium redox battery (VRB) is the most prevalent flow battery type and is suitable for longer durations of up to 8 hours or where an extended lifetime is required. Despite their low energy capacity and charge/discharge rate, flow batteries respond quickly and reduce fire risk due to the non-flammable electrolytes used.

Zinc Bromine, cerium-zinc

A zinc-bromine battery is a rechargeable battery that uses the reaction between bromine and zinc metal to produce an electric current with an electrolyte composed of an aqueous solution of zinc bromide. The zinc-bromine battery was developed as an alternative to lithium-ion batteries for stationary power applications from grid-scale to domestic scale. The water-based electrolyte in Zinc-bromine batteries makes the battery system less prone to fire and overheating than lithium-ion batteries.

BESS Applications

Battery energy storage can be beneficial for several reasons due to the flexibility of co-locating with other renewable energy sources or non-renewable sources. Battery energy storage also requires a relatively small footprint and is not constrained by geographical location. Let’s consider the below applications and the challenges battery energy storage can solve.

Peak Shaving / Load Management (Energy Demand Management)

A battery energy storage system can balance loads between on-peak and off-peak periods. The electricity demand fluctuates depending on the day of the week, time of day, and seasonality. As such, when there is peak electrical demand, prices are at their most expensive. Alternatively, the power price is at the standard rate when demand is low during off-peak periods. Peak shaving allows users with battery energy storage systems the assets to store power during off-peak periods and discharge during peak times to reduce electricity costs.

Energy Time Shifting / Arbitrage

Energy time shifting or arbitrage allows users with BESS solutions to store their purchased power during off-peak times to use on-site when the imported power price is high. Alternatively, users can trade their stored electricity via the flexibility markets (Energy Markets, Ancillary Services, and Capacity Market) for income generation.

If you want to learn more, please visit our website CHANGINGTECH.

Energy Resilience

Battery energy storage can supply fast response backup power in the event of a mains failure to ensure infrastructure is operational and downtime is minimal. Using these battery energy storage systems alongside power generation technologies such as gas-fired Combined Heat and Power (CHP), standby diesel generation, and UPS systems will provide increased resilience mitigating a potential loss of operational costs, whilst protecting your brand.

Frequency Response

A BESS has a frequency response which allows it to provide active power output when there is a change in the electrical grid's frequency. A deviation from the nominal frequency indicates a mismatch between power supply and demand, which can destabilise the grid, causing outages or blackouts. To restore balance quickly, the BESS can adjust its active power output by reacting to deliver sub-second frequency response to stablise and balance supply and demand within the network. The growing share of renewable generation and decentralised power plants connected to the network, means battery storage will continue to play a critical role in our energy transition.

Grid Connected

In Front-of-the-Meter (FtM) applications battery storage systems are typically referred to as utility or grid-scale battery storage and can be connected to transmission or distribution networks to reduce congestion management whilst also controlling voltage and providing reserve and ancillary services. A BESS can also support power generation assets.

Commercial and Industrial

BESS are typically Behind-the-Meter (BtM), and applications include avoiding electricity network charges, benefiting from tariff differences, delivering value-added balancing services, or enhancing on-site resilience and energy consumption when paired with on-site solar PV, thus saving money and optimising the sustainability benefits.

Co-location

BESS can be paired with other renewable and non-renewable technologies to form a hybrid power solution. For example, these hybrid systems can enhance the performance of new and existing gas engine installations. Combining a battery storage system with gas generation and solar power will go a long way to making cheaper, cleaner and more reliable power more accessible.

What are the sources of BESS revenues?

BESS projects can be attractive by obtaining ‘stacked’ revenue streams. These include:

Capacity Markets

Participants may earn revenue for entering into commitments under a statutory contract called a ‘Capacity Agreement’ with the Government. These Capacity Agreements provide a backup electricity supply to meet peak demand during system stress. The agreements may have a duration of up to 15 years.

Offtake Agreements

These agreements are with the consumers for a negotiated price. The contracts are known as Power Purchase Agreements or PPA. PPAs may have a duration of up to 15 years.

Dynamic Frequency Response

Dynamic Frequency Response provides an extremely valuable source of income. However, contracts with the National Grid typically have two years. Under the dynamic frequency response contracts, the operator responds to fluctuations in demand on the network by reducing or increasing its energy consumption. This is organised through the Dynamic Containment Service.

Energy Arbitrage

Users with BESS assets can optimise their energy usage to lower costs, improve sustainability or reduce costs. Electricity can be purchased and stored when prices are cheap and discharged during peak times to offset energy costs.

DS3 Programme

The main driver for battery storage in Ireland is the DS3 (Delivering a Secure Sustainable Electricity System) programme, which was brought in to enable Ireland to meet its renewable energy targets and to manage the increased amount of renewable generation connected to the grid.

The DS3 programme allows the system operator to procure ancillary services, including frequency response and reserve services; the sub-second response needed means that batteries are well placed to provide these services.

What are alternatives to BESS on energy storage?

Aside from battery energy storage systems, other energy storage technologies include:

Pumped Hydro

During periods of low electricity demand, surplus generation is used to pump water from a low-elevation reservoir up to a high-level elevation. When water is released from the high-level elevation, it flows down through a turbine to generate electricity to meet peak demand.

Compressed Air

Electricity is used to compress ambient air, which is stored under pressure in underground caverns or containers. When electricity demand is high, the pressurised air is heated and released into an expansion turbine generator for power production.

Flywheels

It is a way by which mechanical energy may be stored in the form of potential or kinetic energy. Electric motors accelerate a flywheel at high speeds through which the energy is stored as kinetic rotational energy. When there is an electricity demand, the spinning force of the flywheel is connected to a generator to produce power.

Thermal Energy

Electricity may produce thermal energy, which can be stored until needed. For example, electricity can be used to make chilled water during low demand and later used for cooling during peak electricity consumption. The UK's gas system distributes about twice as much energy as electricity, and this energy is used for heating. Heating demands vary with season and time of day, and thermal energy storage can load shift and smooth demand on the plant. Move heat from the summer to the winter.

The Role of Compressed Air Energy Storage in Comparison to Other ...

Energy storage systems (ESS) store excess electric energy during high-supply and low-demand periods to optimize energy use during peak-demand sessions. Energy storage makes the grid system more secure, flexible and reliable than traditional energy backup solutions like solar and wind power. It boasts numerous environmental and economic benefits, including increased production of renewable energy and decreased carbon emissions.

It also saves you money because it reduces the use of inefficient energy-generating units that only run at peak times and prevents costly business disruption caused by power outages. Most energy storage methods can store energy anywhere along the grid to make commercial and industrial facilities more resilient. They’re also customizable to meet your unique needs. Below, we get into the different types of energy storage methods and why compressed air energy storage is preferable.

How Is Energy Stored?

Energy storage occurs when there’s a greater supply of electricity than demand. The excess electricity is converted to a different form, such as kinetic, chemical or thermal energy, which is often easier and more convenient to store. It’s stored and utilized later when there’s greater demand than supply or the most expensive, making the power grid efficient and reliable.

Types of Energy Storage Systems

There are many types of electrical energy storage systems. Below, we discuss some common ones, highlighting the top advantages and disadvantages of each.

1. Pumped Hydropower Storage (PHS)

Pumped hydroelectric storage accounts for 94% of all the stored energy globally. With PHS, surplus electricity generated during low-cost, off-peak electric power periods is used to pump water from a lower reservoir to an up-hill reservoir. When the demand increases, the water flows down to a lower basin via gravity. As the water flows, it turns turbines that drive a generator rotor that converts the hydropower into electrical energy.

While the infrastructure for hydropower plants can last for decades, they’re expensive to construct and limited by topography and geographical conditions. It’s also not entirely efficient because it loses quite a bit of energy as the water is being pumped. PHS is still a good option if you’re looking for a renewable electricity source that doesn’t produce greenhouse gases.

2. Flywheel Energy Storage

Flywheel energy storage systems convert electric energy into kinetic or rotational energy and store it in this form. The flywheel system is a type of rotor that consists of a mass of wheels that spin around an axis at high speeds to convert electricity to kinetic energy. When the need arises, the flywheel sends the rotational energy through the spinning wheels again, which act as a generator to convert it back to electrical energy.

Most flywheel systems have magnetic bearings around the high-strength composite rotors to prevent energy loss. They also operate in a vacuum to decrease drag and are able to produce high amounts of energy by rotating at speeds of up to 60,000 revolutions per minute.

Flywheel energy storage systems have a modular design that requires minimal maintenance, but they have a small capacity and short discharge duration. Its main disadvantage is that external shocks and mechanical stress can lead to failure.

3. Battery Energy Storage

Battery energy storage systems (BESS) use various types of rechargeable batteries to store electric energy from renewable sources, like wind and solar. BESS, used for large-scale operations, utilizes lithium-ion, lithium-iron iron or lead-acid batteries to store operations until needed. Flow (fuel cell) batteries are another BESS option you can use. They substitute solid electrodes with energy-dense electrolytes such as bromine-hydrogen and hydrogen lithium separated by a membrane that facilitates ion exchanges as the liquid circulates.

The electric energy is stored as direct current (DC) produced by photovoltaic (PV) modules. However, this has to be converted back to alternating current (AC) using an inverter for domestic purposes. Battery energy storage systems are expensive because you need more to purchase the power conversion system (PCS), which includes the inverter. Additionally, they have a shorter life span with higher maintenance requirements.

4. Compressed Air Energy Storage

Compressed air energy storage (CAES) systems store excess energy in the form of compressed air produced by other power sources like wind and solar. The air is high-pressurized at up to 100 pounds per inch and stored in underground caverns or chambers. The air is heated and expanded using a turbine before being converted into electricity via generators when the power supply is reduced and demand is high.

CAES systems are suitable for large-scale electricity storage needs. They can also be used to power pneumatic tools for various applications and industries, including woodwork, furniture assembly, construction and welding. While they’re less efficient than battery and hydropower energy storage systems, CAES systems boast a host of other advantages.

Advantages And Disadvantages Of Compressed Air Energy Storage Over Other Energy Storage Sources

The main advantage of compressed air energy storage is that it’s more affordable and easier to implement than other energy storage solutions.You also save quite a bit on installation and implementation when compared to solutions such as PHS. Other compressed air energy storage benefits include:

  • Unlike the other energy storage solutions, CAES is not limited by application. It can be used for small-scale energy use as well as large-scale energy grids.
  • Compressed air energy storage is more sustainable and less environmentally harmful because it does not require chemicals or other toxic materials to operate.
  • It’s also simple to operate and requires minimal maintenance.
  • Compressed air energy storage capacity is higher than any other energy storage system.
  • CAES systems offer “black start” capabilities that enable operations to continue without an external power supply in case of power failure.

While seemingly perfect, CAES systems have a few disadvantages that limit their extensive adoption. Some of these disadvantages include:

  • Significant energy loss, especially during compression and decompression of the air, limits the compressed air energy storage efficiency compared to other energy storage sources.
  • CAES relies on energy from other sources to expand and decompress the pressurized air. This is less than ideal, especially when fossil fuels are used to facilitate the heating.

Get Quality Air Compressors and Accessories from Quincy Compressor

Compressed air systems can help you power a facility’s machinery, tools and other resources needed to perform essential tasks. Quincy Compressors is a global leader in air compressor and industrial air pump technology that’s been in operation since . We provide you with a rich inventory of high-quality compressors you can count on for decades of use in major industrial environments.

Contact us to discuss your requirements of Small-scale Industrial-Commercial Energy Storage Systems. Our experienced sales team can help you identify the options that best suit your needs.